introduction

Pump with Direction Control Valve configured Relief,Spool at raise or neutral position, to protect the system.2-line installation fit for intermittent operation only,3-line installation fit for continuous or intermittent operation.Manual and pneumatic operation .customer can replace parts to switch operation way.Max pressure : 175/210 bar,Speed range :600-2400 RPM

Code Table

G/C 102 _L AS- 20
Series Type of Mount Rotation Control Mode Displacement in³/r
C 101=Remote Mount R=Right(Clockwise) AS=Airshift Control 20 = 5.10 (83.6)-C101 & C102 only
G 102=Direct Mount L=Left(Counterclockwise) MS=Manual Operation 25 = 6.38 (104.6) – C101 & C102 only
X=For 101 Type 0.7 = 1.48 (24.3)-G101 &G102 only
1.5= 2.96 (48.5) – G101&G102 only
2= 3.94 (64.6)-G101 & G102 only

Bushing series pressure and displacement

Code G101/102 C101/G102
Gear Width 07 15 20 20 25
Code 3/4″ 1-1/2″ 2″ 2″ 2-1/2”
Theoretical      Displacement 1.48 2.95 3.94 5.1 6.38
24.2 48.4 64.6 83.6 104.5
Max Pressure Continuous 3000 3000 2500 2500 2500
210 210 175 175 175
Speed RPM 600-2400 600-2400

Flow and Power data at 2500 PSI (172 bar)

Speed RPM Gear Width Output (gpm/lpm) and Inches (HP/KW)
G101/102 C101/102
3/4“ 1-1/2″ 2″ 2″ 2-1/2″
Flow Power Flow Power Flow Power Flow Power Flow Power
900 17.5 8 38 15 51 19 66 26 83.5 32
4.6 11 10 20 13.5 25 17.5 34 22 42
1200 24.5 11 53 20 70 25 91 34 114 42
6.5 14 14 26 18.5 33 24 45 30 56
1500 31.6 13 66 24 89 31 117 42 148 51
8.3 17 17.5 33 23.5 42 31 56 39 69
1800 38.8 15 81.5 29 110 37 142 50 178 61
10.3 21 21.5 39 29 50 37.5 67 47 82
2100 45.8 18 94.5 34 129 43 167 58 208 72
12.1 24 25 45 34 58 44 78 55 96
2400 52.9 20 110 38 148 49 193 66 240 82
14 27 29 51 39 66 51 89 63.5 110

Dimension Date

A B C D E F
G102 SAE B 1.62 2.94 1.50(07) 2.25(15) 2.75(20) 11.25+D 4
C102 SAE B 1.62 3.37 2.75(20) 3.25(25) 13.25+D 4
G H I J K
G101 0.25 1.94 1.00 1.50(07) 2.25(15) 2.75(20) 10.43+J
C101 0.25 2.38 1.00 2.75(20) 3.25(25) 12.75+J

Installation and Operation

2- line installation fit for intermittent use only;

3- line installation fit for continuous or intermittent use.

When Installing Air  Shifter

Lubricate all moving parts before assembly

Do not over tighten the mounting bolts

Operate the spool by air to inspect